Avent
WOOD PELLET STOVE
NOTE: THESE INSTRUCTIONS MUST BE SAVED for future reference
HOT WHILE IN OPERATION -KEEP CHILDREN, CLOTHING AND FURNITURE AWAY - CONTACT MAY
CAUSE SKIN BURNSPLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS
PELLET BURNING STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR EVEN DEATH.
IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory.
When you call have your serial number, purchase date, who installed the unit and a list of questions.
AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE
INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY
CONSEQUENTIAL DAMAGE(S).
AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350
Web Site: www.hearthdirect.com Rev. date 05/05/04
9 When installing your Avent Wood Pellet stove, particular attention needs to be made in regards to fire
protection. If the unit is not properly installed, a house fire may result. For your safety, follow the
installation and operation instructions provided. Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
9 Read the operations and fuel section of this manual before plugging in your unit.
9 Always unplug the unit before attempting any service work.
9 Do not connect the unit to a chimney flue already serving another appliance.
9 When installing the chimney pipe to the unit, it is important to remember that the unit operates on a
positive pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings
must be airtight. (proper venting practices must be followed. Consult with a venting professional)
9 Ashes must be disposed of in a metal container with a tight fitting lid.
9 All minimum clearances to combustibles must be followed.
9 The Avent Wood Pellet Stove is tested for operation with wood pellets with ash content of no more than
2%. It is recommended that wood pellets with an ash content of 1% or less be used for efficient
operation of this unit. For use with wood pellets, cherry pits, olive pits or other pelletized fuel.
9 It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you
the same fuel each time that you purchase. It is recommended that you purchase your entire heating season
supply of fuel at one time so that the fuel will be the same.
9 A voltage surge protector or ground fault outlet is required for this unit. The warranty will be
voided if surge protection is not installed before operating this unit.
9 A grounded outlet must be provided with proper polarity. A constant 115 volt, 60 cycles must be
provided for proper operation or the warranty of this appliance will be forfeited.
9 Special attention needs to be taken to clean out the top heat exchangers of this unit on a regular
basis. The fly ash from the venting settles on the top heat exchangers and must be cleaned off to
keep the unit operating properly. Check for plugging every one-two weeks or when needed.
9 If unit is not operated for extended periods of time (like summer) unplug the unit and disconnect the
battery to assure long life of electrical components.
9 This appliance has been tested to ASTM E1509 ULC C1482standards by
OMNI-Test Laboratories, Inc.
9 The authority having jurisdiction (such as municipal building dept., fire dept., fire prevention
bureau, etc.) should be consulted before installation to determine the need to obtain a permit.
9 If smoke detectors are installed close to the appliance, they may go off if the stove door is left open or
if there is not ade
q
uate fresh air for the a
pp
liance to o
p
erate
p
ro
p
erl
y
.
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - WOOD PELLET STOVE

Avent WOOD PELLET STOVE NOTE: THESE INSTRUCTIONS MUST BE SAVED for future reference HOT WHILE IN OPERATION -KEEP CHILDREN, CLOTHING AND FURNITURE

Page 2 - TABLE OF CONTENTS

109 Distance from doors and windows, gravity or ventilation air inlet into building: Not less that 4 ft. / 1.2 m below, 4 ft. / 1.2 m horizontally f

Page 3 - Technical Bulletin

11GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN, CONT…… To determine whether a 3” or 4” exhaust system should be used, follow the guidelines below:

Page 4 - AVENT TECHNICAL DATA

12 OUTSIDE MAKE-UP AIR FOR COMBUSTION IS REQUIRED ON ALL INSTALLATIONS 1) For FREESTANDING installations with horizontal through-the-wall exhaust

Page 5 - SPECIFICATIONS

13OUTSIDE AIR DIAGRAM WARNING: ROOM AIR STARVATION CAN CAUSE THE APPLIANCE TO MALFUNCTION, BURN DIRTY AND SH

Page 6 - SAFETY STEPS

14 The Avent Wood Pellet Stove may be installed as follows: 1) A freestanding unit (with a pedestal only) 2) A built-in heater mounted in an alc

Page 7 - WOOD PELLETS

15ALCOVE INSTALLATION REQUIREMENTS The Avent Wood Pellet is approved for the standard alcove height of 56 inches, or for a reduced alcove height wit

Page 8

163) NOTE: Make sure that you leave enough clearance between the wall and the back of the unit so that you will be able to install the outside air

Page 9

17• STANDARD VERTICAL INSTALLATION Your Avent Wood Pellet Stove comes to you with the glass door installed in place, ready for use. The glass

Page 10

18CLEANING THE GLASS When the fire is first started, it will produce some smoke. The smoke might accumulate on the glass surface. Before the fire

Page 11 - MAXIMUM

19Diagram of heat exchanger cleaning/disassembly of top section Diagram of Circuit Board Components .250 Terminal Spade (back of board) Th

Page 12

2TABLE OF CONTENTS TECHNICAL BULLETIN: IMPORTANCE OF FRESH AIR PAGE 3 AVENT TECHNICAL DATA / ESTIMATED FUEL FEED RATE CHART………………. 4 INTRODUCTION &

Page 13

20 NOTE: This appliance is designed to burn premium wood pellets, olive pits or cherry pits. Do not burn corn or any other fuel. Do not overf

Page 14 - CAUTION

21Turning the appliance off: Move the power switch to the “off” position. The fan will continue to run for approximately 10-15 minutes to let the a

Page 15

22 9 If the flame does not have enough draft, fuel will build up in the firepot and eventually smother the flame. If this happens, or if you notice

Page 16

23SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS: Diagram of heat exchanger cleaning/disassembly of top section Replace the hea

Page 17

24 9 Power Outage During a power outage, the stove will shut down safely. It will not automatically restart when the power returns, unless t

Page 18 - STOVE CONTROLS

25need to have the thermostat 6-10 feet away from the stove. Please follow the thermostat manufacturer’s instructions carefully. 9 The circuit boa

Page 19

2612 volt DC wiring installation The Avent pellet stove is designed to operate on a 12 volt DC battery system for extended back-up periods. This sys

Page 20

27 PROBLEM CAUSES SOLUTIONS ? Fire burns with a lazy, orange flame and/or fuel builds up in the grate and the window gets sooted up. ♦ Insuff

Page 21 - SETTING THE DRAFT

28PROBLEM CAUSES SOLUTIONS ? Fire goes out or stove shuts down automatically. ♦ Hopper is empty. ♦ Fuel is not feeding. ♦ High limit temper

Page 22 - MAINTENANCE INSTRUCTIONS

29 PROBLEM CAUSES SOLUTIONS ? Blower will not operate. ♦ No power to stove. ♦ No power to control board. ♦ Blower is defective

Page 23

3Technical Bulletin Importance of adequate fresh air Every home is a slightly different situation and depending on the design of the air movement w

Page 24 - AUTOMATIC SAFETY FEATURES

30IMPORTANT: ELECTRICAL WORK MUST BE PERFORMED BY AN AUTHORIZED TECHNICIAN. WARNING: THIS SECTION IS ONLY FOR QUALIFIED TECHNICIANS. Avent Wood Pel

Page 25

31 5 YEAR LIMITED WARRANTY This warranty is issued by American Energy Systems, Inc. (Manufacturer) and extends only to the original purchaser of th

Page 26

32SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED

Page 27 - TROUBLE SHOOTING GUIDE

AVENT TECHNICAL DATA ESTIMATED FUEL FEED RATE CHART The fuel feed rates shown can vary as much as 30-50% depending on fuel quality. WOOD PELLETS:

Page 28

5DEAR VALUED AVENT OWNER, We appreciate your decision to help preserve our precious environment by purchasing the Avent Positive Draft Wood Pellet A

Page 29 - Replacement Parts List

6 IMPORTANT: Proper installation of this stove is crucial for proper and safe operation. Installing this product improperly may result in a house

Page 30 - Transforme

7 Unlike petroleum and natural gas products, solid fuels such as wood pellets create ash as the fuel is burned. Even with the highly efficient fl

Page 31 - 5 YEAR LIMITED WARRANTY

8 When you receive your Avent Wood Pellet Stove be careful to inspect all parts and components to make sure that nothing was damaged or lost in sh

Page 32 - SERVICE RECORD

9 It is recommended that only an authorized Avent Wood Pellet installer install your wood pellet stove. The followin